Monday, August 28, 2017

Xcel Gas Meter Clearances

METER GUARD J-95 DESIGN AND INSTALLATION - Pacific Gas And ...
Gas Distribution and Technical Services J-95 Department: Section: Gas Engineering and Planning Physical protection shall be provided for any gas meter set located in one of the areas described below: 1. Type 1 Locations Within 3’ of the following: ... View Full Source

Section 4 Underground Service - SnoPUD - Snohomish County PUD
Meter base or CT can to the District's point of service. 3. In general, 5. Gas lines shall be staked every 10' as required to maintain separation. 6. Section 4. Underground Service 4 ... Return Document

4725.2150 REQUIRED DISTANCE FROM GAS PIPES, LIQUID PROPANE ...
187 4725.2150 REQUIRED DISTANCE FROM GAS PIPES, LIQUID PROPANE TANKS, AND ELECTRIC LINES. Subpart 1. General distances. The minimum isolation distances in item A or B ... Return Doc


Obtain Energy Meter Usage Data – Xcel Energy tenants have some energy meters they pay to Xcel Energy for either electricity or natural gas), Xcel Energy can provide you with an energy report containing aggregated data for the whole ... Read Here

Previous Year Project Upon Completion 2013-2018 ~ CDOT ...
Previous Year Project upon completion Current Project, Design Phase Current Project, - XCEL: Gas- , Elect-UGE will be included in this project (not 1%), PS and connects meter needed for street and ped-lighting, signals, VMS. ... Read Content

Dry Utilities Service Guidelines - Home Builders Association ...
Xcel Energy Gas and Electric . Electric Cooperatives Service Areas . Dry Utilities Service Guidelines for Developers & Builders Step 1 Application The first step of owning the process is completing the required applications for service. ... Return Doc

PADMOUNT EQUIPMENT LOCATIONS / CLEARANCES
PADMOUNT EQUIPMENT LOCATIONS / CLEARANCES Gas service meter relief vents. 3 ft Fire sprinkler values, Clearances between pad mount equipment and structures must be measured from the closest metal portion of the equipment ... Doc Retrieval

INFORMATION ELECTRIC SERVICE
Service Drop Clearances..11 Clearance of Trees from Power Lines ..11 Mobile Homes Meter Location ... Retrieve Here

CLEARANCES AND LOCATION REQUIREMENTS FOR 051122 ENCLOSURES ...
CLEARANCES AND LOCATION REQUIREMENTS FOR ENCLOSURES, PADS, AND UNDERGROUND EQUIPMENT Prepared by: ABB1 This document is also included in the following manual: • Electric and Gas Service Requirements Manual (Greenbook) Purpose and Scope ... Read Document

Utility Pole - Wikipedia
Other common utility pole materials are steel and concrete, with composites (such as fibreglass) Steel poles can provide advantages for high-voltage lines, where taller poles are required for enhanced clearances and longer span requirements. ... Read Article

Electric Service Standards - FPL - FPL | Homepage
Service and Meter Connections . V. Requirements for Transformers Situated on Customer Property . Standards, in addition to any new or other pertinent information that may not be published. Minimum Vertical Clearances .. 10 . Attachment of Service Drop at Buildings - to the Pipe Mast ... View This Document

EXAMPLES OF DOMESTIC METER SET INSTALLATIONS
EXAMPLES OF DOMESTIC METER SET INSTALLATIONS *15-1/2”+/- *6”+/- Side Out *24 Example of the Minimum Clearances for Outside Meter sets: Meter Set Requirements It is the responsibility of the customer TO TIE the house line / fuel line into the meter bar at the Customer Gas Valve (CGV) ... Access Full Source

RESIDENTIAL ELECTRICAL SERVICES Connection And General ...
RESIDENTIAL ELECTRICAL SERVICES . Connection and General Information . Page 1 . TABLE OF CONTENTS . CLEARANCES AND METER HEIGHT Gas Cascade Natural Gas : (800) 552-0615 ... Doc Viewer

Location Requirements For Natural gas Installations
Minimum clearances for gas meter installation (Some cities may require greater distances.) • 3' from fresh air intake or any opening to building Natural gas meter location requirements (May vary by city) • Minimum of 2' from property line ... Read More

Glossary Of Terms - Xcel Energy
Clearances Interruptions in electrical service in order to who receives Xcel Energy's contract for gas and/or electric service. This person is gas distribution facilities to the meter and then ... Read Content

Section 8—Meters And Meter Sockets - Rochester Gas And Electric
Gas meter 6" separation between a gas meter/regulator and an electric meter and/or meters must be 1 foot minimum and 6 inches on the outlet side of the gas meter bar. there must be 12 inches on all sides and 4 feet of clear space, suitable for a worker, ... Document Viewer

Gas Appliances And Gas Piping
Record of Revisions March 15, 2017 – Rev 2.01 Gas Appliances and Gas Piping iii Record of Revisions Revision Number Revision Date Sections Revised Reason for Revision ... Read Here

APPENDIX E METERS AND GAS SERVICE PIPING - Iccsafe.org
APPENDIX E METERS AND GAS SERVICE PIPING E.1 General. This appendix addresses the requirements for metersandservicepiping,underground oraboveground, asthe Gas meter rooms, when provided, shall at all times be keptclearofallrubbish;andshallnotbeusedinanyway ... Read Here

NATURAL GAS SERVICE AGREEMENT NEW RESIDENTIAL SERVICE
NATURAL GAS SERVICE AGREEMENT NEW RESIDENTIAL SERVICE. CNP 387 (4-2009) Invisible fences Sewer lines. responsible for all costs to relocate the meter. Minimum clearances for gas meter installation - - - - - -Site must be within 6" of final grade ... Access Full Source

SERVICE ENTRANCE REQUIREMENTS MANUAL
SECTION 1: Temporary Construction Meter Poles SECTION 6: Clearances Service Entrance Requirements Manual. BTU will inspect the service entrance to the first means of disconnect for conformity. BTU does not, however, ... Retrieve Content